Chapter 1 Getting Started© National Instruments Corporation 1-3 NI PXI-1052 User Manual• Over-current protection through push-reset circuit breaker (n
Chapter 1 Getting StartedNI PXI-1052 User Manual 1-4 ni.comChassis DescriptionFigure 1-1 and Figure 1-2 show the key features of the PXI-1052 chassis
Chapter 1 Getting Started© National Instruments Corporation 1-5 NI PXI-1052 User ManualFigure 1-2. Rear View of the PXI-1052 ChassisOptional Equipmen
Chapter 1 Getting StartedNI PXI-1052 User Manual 1-6 ni.comInteroperability with CompactPCIThe PXI-1052 backplane is interoperable with 5 V and univer
Chapter 1 Getting Started© National Instruments Corporation 1-7 NI PXI-1052 User ManualLocal BusThe PXI backplane local bus is a daisy-chained bus tha
Chapter 1 Getting StartedNI PXI-1052 User Manual 1-8 ni.comSystem Reference ClockThe PXI-1052 supplies the PXI 10 MHz system clock signal (PXI_CLK10)
© National Instruments Corporation 2-1 NI PXI-1052 User Manual2Installation and ConfigurationThis chapter describes how to install, configure, and use
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-2 ni.com• Modification—Do not modify any part of the chassis from its original condi
Chapter 2 Installation and Configuration© National Instruments Corporation 2-3 NI PXI-1052 User ManualTip Install the chassis so that you can access t
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-4 ni.comConnecting Safety GroundCaution The PXI-1052 chassis is designed with a thre
Worldwide Technical Support and Product Informationni.comNational Instruments Corporate Headquarters11500 North Mopac Expressway Austin, Texas 78759-3
Chapter 2 Installation and Configuration© National Instruments Corporation 2-5 NI PXI-1052 User ManualPower Switch LED IndicatorsThe chassis has two L
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-6 ni.comInstalling a PXI ControllerThis section contains general instructions for in
Chapter 2 Installation and Configuration© National Instruments Corporation 2-7 NI PXI-1052 User Manual3. When you begin to feel resistance, pull up on
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-8 ni.comInstalling PXI ModulesNote Remove any rubber thread protectors from the PXI
Chapter 2 Installation and Configuration© National Instruments Corporation 2-9 NI PXI-1052 User ManualFigure 2-4. Installing PXI or CompactPCI Module
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-10 ni.comInstalling SCXI ModulesNotes Remove any rubber thread protectors from the S
Chapter 2 Installation and Configuration© National Instruments Corporation 2-11 NI PXI-1052 User Manualsoftware on the NI Driver CD, the MAX icon is p
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-12 ni.com4. Click the PXI System controller entry. The chassis (or multiple chassis,
Chapter 2 Installation and Configuration© National Instruments Corporation 2-13 NI PXI-1052 User ManualUsing System Configuration and Initialization F
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-14 ni.com5. Click Finish. A configuration window opens. Refer to the DAQ Quick Start
Important InformationWarrantyThe NI PXI-1052 is warranted against defects in materials and workmanship for a period of one year from the date of ship
Chapter 2 Installation and Configuration© National Instruments Corporation 2-15 NI PXI-1052 User Manual6. Click Details for more configuration options
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-16 ni.comNote You need not adjust the information in the cabling tab if you are usin
Chapter 2 Installation and Configuration© National Instruments Corporation 2-17 NI PXI-1052 User ManualIn Traditional NI-DAQ, you configure virtual ch
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-18 ni.com– In LabWindows™/CVI™, select Tools»Create/Edit DAQmx Tasks. – In Measureme
Chapter 2 Installation and Configuration© National Instruments Corporation 2-19 NI PXI-1052 User Manual– In LabWindows/CVI or Measurement Studio, you
Chapter 2 Installation and ConfigurationNI PXI-1052 User Manual 2-20 ni.comYou can use the Inhibit signal (active low) to power off the chassis. To re
Chapter 2 Installation and Configuration© National Instruments Corporation 2-21 NI PXI-1052 User ManualCautions When connecting digital voltmeter prob
© National Instruments Corporation 3-1 NI PXI-1052 User Manual3MaintenanceThis chapter describes basic maintenance procedures you can perform on the P
Chapter 3 MaintenanceNI PXI-1052 User Manual 3-2 ni.comCleaningCaution Always disconnect the AC power cable before cleaning or servicing the chassis.C
Chapter 3 Maintenance© National Instruments Corporation 3-3 NI PXI-1052 User ManualCleaning and Replacing the Fan FiltersNote Power off the chassis an
© National Instruments Corporation v NI PXI-1052 User ManualContentsAbout This ManualConventions ...
Chapter 3 MaintenanceNI PXI-1052 User Manual 3-4 ni.com5. Verify that the PXI-1052 can meet the power requirements of the installed CompactPCI, SCXI,
© National Instruments Corporation A-1 NI PXI-1052 User ManualASpecificationsCaution If the PXI-1052 chassis is used in a manner inconsistent with the
Appendix A SpecificationsNI PXI-1052 User Manual A-2 ni.comPower disconnect...The AC power cable provides main power
Appendix A Specifications© National Instruments Corporation A-3 NI PXI-1052 User ManualOver-current protection... All outputs p
Appendix A SpecificationsNI PXI-1052 User Manual A-4 ni.comNote For UL and other safety certifications, refer to the product label, or visit ni.com/ha
Appendix A Specifications© National Instruments Corporation A-5 NI PXI-1052 User ManualOperating EnvironmentIndoor use onlyAmbient temperature range..
Appendix A SpecificationsNI PXI-1052 User Manual A-6 ni.comBackplaneSize ...3U-sized; one system
Appendix A Specifications© National Instruments Corporation A-7 NI PXI-1052 User ManualWeight... 10 k
Appendix A SpecificationsNI PXI-1052 User Manual A-8 ni.comFigure A-1 and Figure A-2 show the PXI-1052 dimensions. The holes shown are for the install
Appendix A Specifications© National Instruments Corporation A-9 NI PXI-1052 User ManualFigure A-2. PXI-1052 Dimensions (Bottom) in Inches (mm)14.66 [
ContentsNI PXI-1052 User Manual vi ni.comInstalling SCXI Modules...
Appendix A SpecificationsNI PXI-1052 User Manual A-10 ni.comFigure A-3. PXI-1052 Rack Mount Kit Components1 Front Rack-Mount Kit 2 PXI-1052 Chassis 3
© National Instruments Corporation B-1 NI PXI-1052 User ManualBPinoutsThis appendix describes the P1 and P2 connector pinouts for the PXI-1052 backpla
Appendix B PinoutsNI PXI-1052 User Manual B-2 ni.com Table B-1. P1 (J1) Connector Pinout for the System Controller SlotPin Z A B C D E F25 GND 5V REQ
Appendix B Pinouts© National Instruments Corporation B-3 NI PXI-1052 User Manual Table B-2. P2 (J2) Connector Pinout for the System Controller SlotPi
Appendix B PinoutsNI PXI-1052 User Manual B-4 ni.com Table B-3. P1 (J1) Connector Pinout for the Star Trigger SlotPin Z A B C D E F25 GND 5V REQ64#
Appendix B Pinouts© National Instruments Corporation B-5 NI PXI-1052 User ManualTable B-4. P2 (J2) Connector Pinout for the Star Trigger SlotPin Z A
Appendix B PinoutsNI PXI-1052 User Manual B-6 ni.com Table B-5. P1 (J1) Connector Pinout for the Generic Peripheral SlotPin Z A B C D E F25 GND 5V R
Appendix B Pinouts© National Instruments Corporation B-7 NI PXI-1052 User ManualTable B-6. P2 (J2) Connector Pinout for the Generic Peripheral SlotPi
© National Instruments Corporation C-1 NI PXI-1052 User ManualCTechnical Support and Professional ServicesVisit the following sections of the National
Appendix C Technical Support and Professional ServicesNI PXI-1052 User Manual C-2 ni.comIf you searched ni.com and could not find the answers you need
© National Instruments Corporation vii NI PXI-1052 User ManualAbout This ManualThe NI PXI-1052 User Manual contains information about installing, conf
© National Instruments Corporation G-1 NI PXI-1052 User ManualGlossarySymbol Prefix Valueppico10–12nnano10–9µ micro 10–6m milli 10–3k kilo 103Mmega106
GlossaryNI PXI-1052 User Manual G-2 ni.comBbackplane An assembly, typically a printed circuit board, with connectors and signal paths that interconnec
Glossary© National Instruments Corporation G-3 NI PXI-1052 User ManualEefficiency Ratio of output power to input power, expressed as a percentage.EIA
GlossaryNI PXI-1052 User Manual G-4 ni.comIIEC International Electrotechnical Commission; an organization that sets international electrical and elect
Glossary© National Instruments Corporation G-5 NI PXI-1052 User ManualMm Meters.MAX NI Measurement & Automation Explorer, the utility that allows
GlossaryNI PXI-1052 User Manual G-6 ni.comPXI PCI eXtensions for Instrumentation. PXI is an implementation of CompactPCI with added electrical feature
Glossary© National Instruments Corporation G-7 NI PXI-1052 User ManualUUL Underwriter’s Laboratories.VV Volts.VAC Volts alternating current, or Vrms.v
© National Instruments Corporation I-1 NI PXI-1052 User ManualIndexAAC power cables (table), 1-2Bbackplaneinteroperability with CompactPCI, 1-6local b
IndexNI PXI-1052 User Manual I-2 ni.comIinstallationSCXI filler panels, 2-9, 2-10SCXI modules, 2-10installation, configuration, and operationchassis i
Index© National Instruments Corporation I-3 NI PXI-1052 User ManualP2 (J2) connectorperipheral slot (table), B-7star trigger slot (table), B-5system c
About This ManualNI PXI-1052 User Manual viii ni.comRelated DocumentationThe following documents contain information that you might find helpful as yo
IndexNI PXI-1052 User Manual I-4 ni.comSCXI subsystemcontrol slot for PXI peripheral module, 1-7installation, filler panel, 2-10overview, 1-8service i
© National Instruments Corporation 1-1 NI PXI-1052 User Manual1Getting StartedThis chapter describes the key features of the PXI-1052 chassis and list
Chapter 1 Getting StartedNI PXI-1052 User Manual 1-2 ni.comIf you are missing any of the items in Table 1-1, or if you have the incorrect AC power cab
Comments to this Manuals