National Instruments SCC-TC Series Thermocouple Input Modules User Manual

Browse online or download User Manual for Unknown National Instruments SCC-TC Series Thermocouple Input Modules. National Instruments SCC-TC Series Thermocouple Input Modules User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
USER GUIDE
SCC-TC Series Thermocouple
Input Modules
The SCC-TC Series thermocouple input modules, SCC-TC01 and
SCC-TC02, accept input signals from B-, E-, J-, K-, N-, R-, S-, and T-type
thermocouples. Each module contains thermistor circuitry powered by
2.5 V, to compensate for cold-junction effects and can detect open
thermocouple circuits. Each module has one thermocouple input channel,
which consists of a gain of 100 differential amplifier and a dual-pole 2 Hz
filter.
Note Alternatively, you can use the SCC-TC02 as a 2 Hz lowpass bandwidth ±100 mV
input module.
Conventions
The following conventions are used in this guide:
» The » symbol leads you through nested menu items and dialog box options
to a final action. The sequence File»Page Setup»Options directs you to
pull down the File menu, select the Page Setup item, and select Options
from the last dialog box.
This icon denotes a note, which alerts you to important information.
This icon denotes a caution, which advises you of precautions to take to
avoid injury, data loss, or a system crash. When this symbol is marked on
the product, refer to the Read Me First: Safety and Radio-Frequency
Interference document, shipped with the product, for precautions to take.
When symbol is marked on a product, it denotes a warning advising you to
take precautions to avoid electrical shock.
When symbol is marked on a product, it denotes a component that may be
hot. Touching this component may result in bodily injury.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Input Modules

USER GUIDESCC-TC Series Thermocouple Input ModulesThe SCC-TC Series thermocouple input modules, SCC-TC01 and SCC-TC02, accept input signals from B-, E

Page 2 - What You Need to Get Started

SCC-TC Series Thermocouple Input Modules User Guide 10 ni.comSpecificationsThese specifications are typical at 25 °C unless otherwise stated.Analog In

Page 3 - Device Specific Information

© National Instruments Corporation 11 SCC-TC Series Thermocouple Input Modules User GuideMeasurement Accuracy11 Total system measurement error for o

Page 4 - Connecting the Input Signals

SCC-TC Series Thermocouple Input Modules User Guide 12 ni.comCold-Junction SensorCold-junction sensor accuracy...±0.4 °C max from 15 to 3

Page 5 - Using the TC0X

© National Instruments Corporation 13 SCC-TC Series Thermocouple Input Modules User GuideFigure 3. SCC-TC02 DimensionsWeightTC-01 ...

Page 6

SCC-TC Series Thermocouple Input Modules User Guide 14 ni.comEnvironmentalOperating temperature ...0 to 50 °CStorage temperat

Page 7 - Detecting Open Thermocouples

© National Instruments Corporation 15 SCC-TC Series Thermocouple Input Modules User GuideCE ComplianceThis product meets the essential requirements of

Page 8

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal f

Page 9 - Calibrator

SCC-TC Series Thermocouple Input Modules User Guide 2 ni.combold Bold text denotes items that you must select in the software, such as menu items and

Page 10 - Specifications

© National Instruments Corporation 3 SCC-TC Series Thermocouple Input Modules User Guide❑ Documentation– One of the following:• SC-2345/2350 User Manu

Page 11 - Measurement Accuracy

SCC-TC Series Thermocouple Input Modules User Guide 4 ni.comthe inputs of the second-stage SCC. An example of dual-stage conditioning in an SCC-TC0X f

Page 12 - Physical

© National Instruments Corporation 5 SCC-TC Series Thermocouple Input Modules User GuideFigure 1. SCC-TC0X Signal ConnectionsFor more information abo

Page 13 - Maximum Working Voltage

SCC-TC Series Thermocouple Input Modules User Guide 6 ni.comtemperature measurements. To make this conversion, complete the following steps:1. Measure

Page 14 - Electromagnetic Compatibility

© National Instruments Corporation 7 SCC-TC Series Thermocouple Input Modules User GuideDetecting Open ThermocouplesThe SCC-TC0X contains a 10 MΩ pull

Page 15 - I/O Connector Pin Assignments

SCC-TC Series Thermocouple Input Modules User Guide 8 ni.comCold-Junction SensorThe cold-junction sensor voltage output varies from 1.91 to 0.58 V ove

Page 16 - 371074C-01 Jul06

© National Instruments Corporation 9 SCC-TC Series Thermocouple Input Modules User GuideCalibrating System OffsetsTo calibrate the offset voltage of t

Comments to this Manuals