Chapter 7 Advanced Application Topics
BridgeVIEW User Manual 7-26 © National Instruments Corporation
e. Wire the “Disabled” attribute value output of the VI to the
Attribute Node.
f. Invert the shutdown output of the VI and wire it to the
continuation terminal of the While Loop.
g. With the Wiring tool, pop up on the operability access level (0)
input of the Security Monitor VI and select Create Constant.
Enter
50
into the constant.
h. Save the VI as
Alarm Summary with Security.vi
in the
BridgeVIEW\Activity
directory.
The completed block diagram, including the new While Loop with the
Security Monitor VI, is shown in the following illustration.
7. Run the VI. Because you are logged in as
Administrator
, you have
privileges to acknowledge alarms.