Appendix A Specifications
PXI-1006 User Manual A-2 ni.com
DC Output
Maximum usable power .........................600 W
DC current capacity (I
MP
)
Load regulation
Maximum ripple and noise .....................1% ripple, 1% noise
20 MHz bandwidth
Over-current protection...........................105140% of rated output
current; automatic recovery
Over-voltage protection ..........................3.3 V, 5 V clamp at 122134%
of output voltage
+12 V and 12 V clamp at
110120% of output voltage
Power supply/fan unit MTTR.................Replacement in under 5 minutes
Cooling
Module cooling system...........................Forced air circulation
(positive pressurization) via
three 140 cfm fans with
HI/AUTO speed selector
Vo lt age I
MP
(Steady-State Current)
+3.3 V 60 A
+5 V 60 A
+12 V 9A
12 V 1.8 A
Vo lt age Regulation
+3.3 V 0.4% or 20 mV max
+12 V 0.4% or 20 mV max
+5 V 0.4% or 20 mV max
12 V 0.4% or 20 mV max