PXI-1006 User Manual A-4 ni.com
Functional shock (operating) ..................MIL-T-28800E CLASS 3,
Half-Sine Shock Pulse, 11 ms
duration, 30 g peak
Operating location ..................................Indoor use only
Random vibration
Operational
1
.....................................5 to 500 Hz, 0.31 g
RMS
Non-operational
1
.............................10 to 500 Hz, 2.46 g
RMS
EMC emissions.......................................FCC Class A compliant and
EN 55011 Group 1 Class A
Compliant
EMC immunity .......................................Refer to DOC supplied with
chassis for compliance to
relevant directives.
Altitude ...................................................2 km (1.24 mi) max
Backplane
Size .........................................................3U-sized; one system slot
(with three system expansion
slots)and17peripheralslots.
Compliant with IEEE 1101.10
mechanical packaging.
PXI Specification Revision 2.0
compliant.
Accepts both PXI and
CompactPCI (PICMG 2.0 R3.0)
3U modules.
Backplane bare-board material ...............UL 94 V-0 recognized
Backplane connectors .............................Conform to IEC 917 and
IEC 1076-4-101, and are
UL 94 V-0 rated
1
Random vibration profiles were developed in accordance with MIL-T-28800E CLASS 3 and MIL-STD-810E Method 514
Test levels exceed those recommended in MIL-STD-810E for Category 1 (Basic Transportation), Figures 514.4-1 through
514.4-3.