National Instruments FP-AI-112 User Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
FP-AI-112 and cFP-AI-112 10 ni.com
Effective resolution by input range and filter setting
Update period and input bandwidth by filter setting
Normal-mode rejection ..................... 95 dB
Nonlinearity ...................................... 0.0015% (monotonicity
1
warranted over the operating
temperature range)
Input impedance (with power on).....>100 M
Overvoltage protection ..................... ±40 V
Input current
25 °C........................................... 400 pA typ, 1 nA max
70 °C........................................... 3 nA typ, 15 nA max
Nominal
Input Range
With
Overranging
Effective
Resolution
*
at 50 or 60 Hz
Effective
Resolution
*
at 500 Hz
±60 mV ±65 mV 3 µV 25 µV
±300 mV ±325 mV 16 µV 100 µV
±1 V ±1.04 V 40 µV 300 µV
±5 V ±5.2 V 190 µV 1500 µV
±10 V ±10.4 V 380 µV 3000 µV
0–1 V 0–1.04 V 20 µV 300 µV
0–5 V 0–5.2 V 95 µV 1500 µV
0–10 V 0–10.4 V 190 µV 3000 µV
*
Includes quantization errors and typical rms noise.
Characteristic
Filter Settings
50 Hz 60 Hz 500 Hz
Update period
*
1.25–1.75 s 1.05–1.45 s 0.27–0.32 s
Input bandwidth (–3 dB) 13 Hz 16 Hz 130 Hz
*
Applies when all 16 channels are set to the same filter setting. Refer to
the
Update Rate
section for information about calculating the update rate.
1
A characteristic of an ADC in which the digital code output always increases as the
value of the analog input to it increases.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Comments to this Manuals

No comments